| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | Continuous | -0.3 | 45 | V | |
| Output Voltage | VOUT | 0 | 0.2 | V | ||
| Continuous Current | ICONT | 8 | A | |||
| Peak Current | IPEAK | Pulse Width ≤ 1ms | 16 | A | ||
| Power Dissipation | PD | Ta = 25°C | 2.5 | W | ||
| Junction Temperature | TJ | Operating Range | -40 | 125 | °C | |
| Storage Temperature | TSTG | -55 | 150 | °C |
Instructions for RU75N08R:
- Mounting: Ensure the device is mounted on a suitable heat sink to maintain junction temperature within specified limits.
- Input Voltage: Do not exceed the maximum input voltage of 45V to avoid damage.
- Current Handling: The device can handle a continuous current up to 8A. For pulses, ensure pulse width does not exceed 1ms if peak currents above 8A are used.
- Thermal Consideration: Monitor the junction temperature and keep it within -40°C to 125°C for reliable operation.
- Storage: Store in an environment where temperatures range from -55°C to 150°C.
- Power Dissipation: Ensure that power dissipation does not exceed 2.5W at room temperature (25°C). Adjust derating factors as necessary for higher ambient temperatures.
- Output Voltage: Keep output voltage below 0.2V to prevent potential damage or malfunction.
For detailed application notes and further guidelines, refer to the manufacturer's datasheet.