Specifications
SKU: 7065746
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | 4.5 | 5 | 5.5 | V | Operating voltage range |
| Quiescent Current | IQ | - | 20 | - | μA | Current consumption in standby mode |
| Output Current per Channel | IO | - | 1.5 | - | A | Maximum output current per channel |
| Short-Circuit Current | ISC | - | 1.8 | - | A | Current during short-circuit condition |
| Thermal Shutdown | TSD | - | 160 | - | °C | Temperature at which thermal shutdown activates |
| Operating Temperature | Topr | -40 | - | 125 | °C | Operating temperature range |
| Storage Temperature | Tstg | -40 | - | 150 | °C | Storage temperature range |
Instructions for TLE6389-2GV
Power Supply:
- Ensure the supply voltage is within the specified range (4.5V to 5.5V) to prevent damage to the device.
Installation:
- Install the component on a suitable heatsink if continuous high current operation is expected, especially when approaching the maximum operating temperature.
Short Circuit Protection:
- The device includes built-in short-circuit protection, but external fuses or circuit breakers are recommended for additional safety.
Thermal Management:
- Monitor the operating temperature and ensure it does not exceed 125°C to avoid thermal shutdown and potential damage.
Output Configuration:
- Configure outputs according to the load requirements, ensuring each channel does not exceed 1.5A.
Handling:
- Handle with care to avoid electrostatic discharge (ESD) damage. Use appropriate ESD protection measures.
Storage:
- Store in a dry environment within the temperature range of -40°C to 150°C to maintain reliability.
Application Notes:
- Refer to the manufacturer’s application notes for detailed guidelines on optimal performance and troubleshooting.