Specifications
SKU: 1403416
Thyrister Output Photocouplers and Photorelays; Features: Standard; Package: DIP6; Surface Mount Type: Y/N; Number of Pins: 6; Trigger LED Current I_FT, max mA: 7; On-state voltage V_TM @I_TM=100mA max V: 1.3; Peak off-state voltage V_DRM max V: 400; Isolation voltage BVs @1minute min V_rms: 5000
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Forward Voltage | VF | IF = 10 mA | 1.2 | 1.6 | V | |
| Peak Forward Current | IFM | t = 1 ms, Repetition Rate = 100/s | 30 | mA | ||
| Reverse Voltage | VR | 5 | V | |||
| Output Current | ICM | tp = 1 ms | 0.5 | A | ||
| Isolation Voltage | VIORM | 1 minute, 50/60 Hz | 5000 | Vrms | ||
| Turn-ON Time | ton | IF = 10 mA, IL = 10 mA | 4 | 6 | μs | |
| Turn-OFF Time | toff | IF = 10 mA, IL = 10 mA | 2 | 4 | μs |
Instructions for Use:
Mounting and Handling:
- Handle the TLP641G with care to avoid mechanical damage.
- Ensure proper heat dissipation if operating at high currents.
Electrical Connections:
- Connect the forward current (IF) source to the appropriate terminals.
- Ensure reverse voltage (VR) does not exceed the maximum rating.
Operating Conditions:
- Operate within specified temperature and humidity ranges to ensure reliable performance.
- Avoid exceeding peak forward current (IFM) and output current (ICM) ratings.
Safety Precautions:
- Respect isolation voltage (VIORM) limits to prevent electrical hazards.
- Implement adequate safety measures when working with high voltages.
Testing and Troubleshooting:
- Measure turn-on and turn-off times under typical conditions to verify correct operation.
- If issues arise, check all connections and ensure parameters are within specified limits.
For detailed specifications and additional information, refer to the official datasheet provided by Toshiba.
(For reference only)Inquiry - TLP641G