| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating condition | 2.7 | - | 5.5 | V |
| Output Current | IOUT | Continuous | - | 1.2 | 1.5 | A |
| Peak Current | IPK | Pulse width = 10ms | - | 2.5 | - | A |
| Quiescent Current | IQ | VOUT = 3.3V | - | 40 | - | μA |
| Dropout Voltage | VDROPOUT | IOUT = 500mA | - | 0.3 | - | V |
| Load Regulation | ΔVO/ΔIL | IOUT: 0mA to 500mA | - | 0.5 | - | % |
| Line Regulation | ΔVO/ΔVIN | VIN: 2.7V to 5.5V | - | 0.1 | - | % |
| Ripple Rejection | RR | f = 120Hz | - | 60 | - | dB |
| Operating Junction Temp | TJ | -40 | - | 125 | °C | |
| Storage Temperature | TSTG | -40 | - | 150 | °C |
Instructions for Use:
- Power Supply Connection: Ensure the supply voltage (VDD) is within the specified range of 2.7V to 5.5V.
- Output Configuration: The device can provide a continuous output current up to 1.5A. For peak currents, ensure not to exceed 2.5A for pulse widths of 10ms.
- Thermal Management: Keep the operating junction temperature between -40°C and 125°C. Consider heat dissipation solutions if necessary.
- Load Regulation: The load regulation is typically 0.5%, meaning the output voltage changes by 0.5% when the load current varies from 0mA to 500mA.
- Line Regulation: Typically at 0.1%, indicating minimal change in output voltage with varying input voltage.
- Ripple Rejection: At 120Hz, the device offers 60dB ripple rejection, ensuring stable output under noisy conditions.
- Storage Conditions: Store the device in environments where temperatures do not exceed -40°C to 150°C.
- Quiescent Current: With an output voltage set at 3.3V, the quiescent current is typically 40μA, which helps in minimizing power consumption.
- Dropout Voltage: Operates efficiently with a typical dropout voltage of 0.3V at an output current of 500mA.
Ensure all connections are secure and within specified limits to avoid damage to the device.
(For reference only)Inquiry - GS-R51212S