| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | V(DS) | - | - | 600 | V | Maximum drain-source voltage |
| Gate-Source Voltage | V(GS) | -20 | - | 20 | V | Maximum gate-source voltage |
| Continuous Drain Current | I(D) | - | 80 | - | A | Continuous drain current at Tc = 25°C |
| Pulse Drain Current | I(D pul) | - | 160 | - | A | Pulse drain current (t(p)=10μs, I(GS)=10A) |
| Power Dissipation | P(TOT) | - | - | 340 | W | Total power dissipation (TC=25°C) |
| Junction Temperature | T(J) | - | - | 175 | °C | Maximum junction temperature |
| Storage Temperature | T(STG) | -55 | - | 175 | °C | Operating temperature range for storage |
Instructions:
Handling Precautions:
- Avoid exceeding the maximum ratings to prevent damage.
- Use appropriate heat sinks when operating at high currents or powers.
Installation:
- Ensure proper mounting to maintain thermal performance.
- Follow manufacturer guidelines for torque specifications on screws if applicable.
Operating Conditions:
- Operate within specified temperature ranges to ensure reliability.
- Monitor the junction temperature especially under continuous load conditions.
Electrical Characteristics:
- Refer to the datasheet for detailed electrical characteristics and typical performance graphs.
- Pay attention to the switching characteristics and timing parameters for optimal circuit design.
Safety:
- Handle with care to avoid static damage.
- Ensure all connections are secure and insulated as necessary.
For more detailed information, refer to the official datasheet provided by IXYS Corporation.